If you see the following message (image below) during pressing, this occurs because there is an obstruction lifting the heat plate safety guard.
If there is no obstruction then the micro switch that activates the safety feature may need adjusting as follows.
There are two micro switches (one on either side of the safety guard), one of which can be seen in the image below.
You will need to adjust the screw so that the switch is 'pressed' and then becomes 'depressed' when the safety guard is lifted.
The process is to undo the nut (blue arrow), adjust the screw (red arrow) so that it holds the switch in the correct position, then tighten the blue nut to hold the adjustment screw in the correct position. Do one side first and test it, then adjust the other side and test again.